ACV · Compact Condens commercial gas boilers · Europe

E07 error code

ACV Compact Condens E07 error code – Flue-gas overtemperature

FaultUnknown2 min read
Unknown priority✓ Source verified
Quick answer

What does ACV Compact Condens commercial gas boilers E07 mean?

ACV documents E07 for Compact Condens 170, 210, 250 and 300 boilers as “Flue-gas overtemperature”. The flue-gas temperature exceeded the permitted maximum.

The code identifies the condition detected by the product; it does not always identify the failed component on its own. Confirm the full code and exact model before ordering parts or attempting a reset.

The ACV Compact Condens commercial gas boilers E07 error code indicates aCV documents E07 for Compact Condens 170, 210, 250 and 300 boilers as “Flue-gas overtemperature”. The flue-gas temperature exceeded the permitted maximum. This guide explains what the code means, the symptoms and likely causes, the checks that are safe to make, and when to stop and arrange an authorised repair.

Symptoms you may notice

The Compact Condens boiler displays E07 and may enter a soft or hard lockout until the detected condition is corrected.

Common causes

Possible causes are those described by ACV for flue-gas overtemperature, including the associated component, wiring, circulation, configuration or safety circuit.

Before you start troubleshooting

Use the display, rating label or product menu to confirm the exact model. Similar-looking codes can have different meanings across product generations and regions.

  • Record the complete code before switching the equipment off.
  • Check only user-accessible controls, filters and external connections described in the manual.
  • Do not open gas, refrigerant, combustion or electrical compartments.

Troubleshooting steps

The heat exchanger may need cleaning. The appliance resets automatically after the flue temperature returns to its normal range.

Can you fix this error code yourself?

The safest next step depends on the exact model and the cause behind the code. External checks may help, but a returning fault needs professional diagnosis.

A successful reset is not proof that the underlying issue is fixed. If E07 reappears, note when it happens and give that information to the service engineer.

Reset instructions

Use only the reset procedure described in the official Compact Condens manual. Hard lockouts require a manual reset; soft lockouts clear only after their cause is resolved. Do not repeatedly reset a returning fault.

Applicable products and models

ACV Compact Condens commercial gas boilers Compact Condens 170, 210, 250 and 300Compact Condens commercial gas boilersCompact Condens 170, 210, 250 and 3002018 onward

When to contact a professional

Contact an ACV-qualified heating engineer if the code returns, the appliance remains locked out, a safety device has operated, or checks require internal access, test equipment or replacement parts.

Frequently asked questions

What does ACV Compact Condens commercial gas boilers E07 mean?

ACV documents E07 for Compact Condens 170, 210, 250 and 300 boilers as “Flue-gas overtemperature”. The flue-gas temperature exceeded the permitted maximum.

Can I fix ACV Compact Condens commercial gas boilers E07 myself?

Some external checks may be suitable for the user, but the result depends on the exact model and cause. Use the official manual and arrange service if the code returns.

Should I reset the product after code E07?

Use only the reset procedure described in the official Compact Condens manual. Hard lockouts require a manual reset; soft lockouts clear only after their cause is resolved. Do not repeatedly reset a returning fault.

When should I arrange a repair?

Contact an ACV-qualified heating engineer if the code returns, the appliance remains locked out, a safety device has operated, or checks require internal access, test equipment or replacement parts.