ACV · Prestige MCBA-5 boiler range · Europe

b117 error code

ACV Prestige MCBA-5 b117 code – Air-pressure switch opened while burner was on

FaultUnknown2 min read
Unknown priority✓ Source verified
Quick answer

What does ACV Prestige MCBA-5 boiler range b117 mean?

ACV documents b117 for the Prestige MCBA-5 range as “Air-pressure switch opened while burner was on”. The code identifies a controller-detected condition and must be interpreted against the exact boiler model and installation.

The code identifies the condition detected by the product; it does not always identify the failed component on its own. Confirm the full code and exact model before ordering parts or attempting a reset.

The ACV Prestige MCBA-5 boiler range b117 error code indicates aCV documents b117 for the Prestige MCBA-5 range as “Air-pressure switch opened while burner was on”. The code identifies a controller-detected condition and must be interpreted against the exact boiler model and installation. This guide explains what the code means, the symptoms and likely causes, the checks that are safe to make, and when to stop and arrange an authorised repair.

Symptoms you may notice

The Prestige controller displays b117; burner, heating or hot-water operation may be interrupted or restricted until the condition clears.

Common causes

Likely causes are those documented by ACV for air-pressure switch opened while burner was on, including the related control, safety, combustion, electrical or circulation circuit.

Before you start troubleshooting

Use the display, rating label or product menu to confirm the exact model. Similar-looking codes can have different meanings across product generations and regions.

  • Record the complete code before switching the equipment off.
  • Check only user-accessible controls, filters and external connections described in the manual.
  • Do not open gas, refrigerant, combustion or electrical compartments.

Troubleshooting steps

Check the air-pressure switch, tubing and air/flue path.

Can you fix this error code yourself?

The safest next step depends on the exact model and the cause behind the code. External checks may help, but a returning fault needs professional diagnosis.

A successful reset is not proof that the underlying issue is fixed. If b117 reappears, note when it happens and give that information to the service engineer.

Reset instructions

Record the code first. Use only the MCBA reset procedure in the official manual and do not exceed the manufacturer's stated reset attempts.

Applicable products and models

ACV Prestige MCBA-5 boiler range Prestige Solo 24, 32, 50, 75 and 120; Prestige Excellence 24 and 32Prestige MCBA-5 boiler rangePrestige Solo 24, 32, 50, 75 and 120; Prestige Excellence 24 and 32Legacy MCBA-5 generation

When to contact a professional

Contact an ACV-qualified heating engineer when the code returns, a safety circuit is involved, or diagnosis requires internal access, measurements, programming or component replacement.

Frequently asked questions

What does ACV Prestige MCBA-5 boiler range b117 mean?

ACV documents b117 for the Prestige MCBA-5 range as “Air-pressure switch opened while burner was on”. The code identifies a controller-detected condition and must be interpreted against the exact boiler model and installation.

Can I fix ACV Prestige MCBA-5 boiler range b117 myself?

Some external checks may be suitable for the user, but the result depends on the exact model and cause. Use the official manual and arrange service if the code returns.

Should I reset the product after code b117?

Record the code first. Use only the MCBA reset procedure in the official manual and do not exceed the manufacturer's stated reset attempts.

When should I arrange a repair?

Contact an ACV-qualified heating engineer when the code returns, a safety circuit is involved, or diagnosis requires internal access, measurements, programming or component replacement.