ATAG · ATAG iC, iS and iR boiler range — 2019 and newer · United Kingdom

112 error code

ATAG 112 error code – Return temperature probe damaged

FaultUnknown2 min read
Unknown priority✓ Source verified
Quick answer

What does ATAG ATAG iC, iS and iR boiler range — 2019 and newer 112 mean?

ATAG identifies code 112 as: Return temperature probe damaged.

The code identifies the condition detected by the product; it does not always identify the failed component on its own. Confirm the full code and exact model before ordering parts or attempting a reset.

The ATAG ATAG iC, iS and iR boiler range — 2019 and newer 112 error code indicates aTAG identifies code 112 as: Return temperature probe damaged. This guide explains what the code means, the symptoms and likely causes, the checks that are safe to make, and when to stop and arrange an authorised repair.

Symptoms you may notice

A temperature or pressure input is missing, damaged or inconsistent, so normal control may be suspended.

Common causes

Failed sensor or probe, damaged wiring, loose connection, or readings that do not agree with the expected operating state.

Before you start troubleshooting

Use the display, rating label or product menu to confirm the exact model. Similar-looking codes can have different meanings across product generations and regions.

  • Record the complete code before switching the equipment off.
  • Check only user-accessible controls, filters and external connections described in the manual.
  • Do not open gas, refrigerant, combustion or electrical compartments.

Troubleshooting steps

Record the complete code and model. A qualified engineer should test the relevant sensor, wiring and live readings before replacing parts.

Can you fix this error code yourself?

The safest next step depends on the exact model and the cause behind the code. External checks may help, but a returning fault needs professional diagnosis.

A successful reset is not proof that the underlying issue is fixed. If 112 reappears, note when it happens and give that information to the service engineer.

Reset instructions

Reset a locked boiler only as described in the ATAG user manual and only after safe external checks. Temporary blocking codes may clear automatically. Do not repeatedly reset a returning fault.

Applicable products and models

ATAG ATAG iC, iS and iR boiler range — 2019 and newer iC; iS; iR; iC EconomiserATAG iC, iS and iR boiler range — 2019 and neweriC; iS; iR; iC Economiser2019 onward

When to contact a professional

Contact ATAG or a Gas Safe registered engineer when the code persists, the boiler locks again, pressure will not remain stable, or internal component testing is required.

Frequently asked questions

What does ATAG ATAG iC, iS and iR boiler range — 2019 and newer 112 mean?

ATAG identifies code 112 as: Return temperature probe damaged.

Can I fix ATAG ATAG iC, iS and iR boiler range — 2019 and newer 112 myself?

Some external checks may be suitable for the user, but the result depends on the exact model and cause. Use the official manual and arrange service if the code returns.

Should I reset the product after code 112?

Reset a locked boiler only as described in the ATAG user manual and only after safe external checks. Temporary blocking codes may clear automatically. Do not repeatedly reset a returning fault.

When should I arrange a repair?

Contact ATAG or a Gas Safe registered engineer when the code persists, the boiler locks again, pressure will not remain stable, or internal component testing is required.