Lockout 4 flashes error code
Lockout 4 flashes — Low system-water pressure
What does Keston Celsius 25 and 25P boilers Lockout 4 flashes mean?
Four red lockout flashes every two seconds indicate that the boiler has detected insufficient system-water pressure.
The code identifies the condition detected by the product; it does not always identify the failed component on its own. Confirm the full code and exact model before ordering parts or attempting a reset.
The Keston Celsius 25 and 25P boilers Lockout 4 flashes error code indicates four red lockout flashes every two seconds indicate that the boiler has detected insufficient system-water pressure. This guide explains what the code means, the symptoms and likely causes, the checks that are safe to make, and when to stop and arrange an authorised repair.
Symptoms you may notice
Red lockout LED flashes four times every two seconds; boiler stops; pressure gauge may read below the required level.
Common causes
System pressure below approximately 0.2 bar; water leak; pressure-switch fault; wiring or control-board fault.
Before you start troubleshooting
Use the display, rating label or product menu to confirm the exact model. Similar-looking codes can have different meanings across product generations and regions.
- Record the complete code before switching the equipment off.
- Check only user-accessible controls, filters and external connections described in the manual.
- Do not open gas, refrigerant, combustion or electrical compartments.
Troubleshooting steps
Check the pressure gauge and visible pipework for leakage. Repressurise only if the exact system instructions permit it. If pressure falls again or the code remains, stop and contact an engineer.
Can you fix this error code yourself?
This fault is not intended for user repair. Do not remove covers or test internal components; record the code and contact an authorised technician.
A successful reset is not proof that the underlying issue is fixed. If Lockout 4 flashes reappears, note when it happens and give that information to the service engineer.
Reset instructions
Only reset after the underlying condition has been checked. Where the official manual permits a reset, turn the boiler user-control knob off, wait, then turn it on again. Do not repeatedly reset a returning lockout.
Applicable products and models
When to contact a professional
Contact a Gas Safe registered engineer if the pattern returns, the boiler will not reset, there is evidence of overheating or leakage, or any check requires access inside the appliance.
Frequently asked questions
What does Keston Celsius 25 and 25P boilers Lockout 4 flashes mean?
Four red lockout flashes every two seconds indicate that the boiler has detected insufficient system-water pressure.
Can I fix Keston Celsius 25 and 25P boilers Lockout 4 flashes myself?
This code is not classed as user-fixable. Record it and arrange authorised diagnosis rather than opening the product.
Should I reset the product after code Lockout 4 flashes?
Only reset after the underlying condition has been checked. Where the official manual permits a reset, turn the boiler user-control knob off, wait, then turn it on again. Do not repeatedly reset a returning lockout.
When should I arrange a repair?
Contact a Gas Safe registered engineer if the pattern returns, the boiler will not reset, there is evidence of overheating or leakage, or any check requires access inside the appliance.