Baxi · Boilers and HVAC

Baxi 600/800 Combi and System 2 boilers

Product information, applicable models, official documentation and 63 indexed error-code explanations for Baxi 600/800 Combi and System 2 boilers.

Baxi 600/800 Combi and System 2 boilers
63indexed codes
1named models or series
1official links
Product overview

About Baxi 600/800 Combi and System 2 boilers

Baxi 600/800 Combi and System 2 boilers is indexed in the Boilers and HVAC directory for United Kingdom. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Baxi 600/800 Combi & System 2
Complete directory

All Baxi 600/800 Combi and System 2 boilers error codes

Showing 1–30 of 63

A.00.28Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomSolar temperature sensor is either removed or measures a temperature below range.Baxi documents A.00.28 for the Baxi 600/800 Combi and System 2 boilers as “Solar temperature sensor is either…A.00.29Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomSolar temperature sensor is either shorted or measures a temperature above range.Baxi documents A.00.29 for the Baxi 600/800 Combi and System 2 boilers as “Solar temperature sensor is either…A.00.34Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomOutdoor temperature sensor expected but not detected.Baxi documents A.00.34 for the Baxi 600/800 Combi and System 2 boilers as “Outdoor temperature sensor expected but…A.02.06Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomLow system pressure in heating circuit.Baxi documents A.02.06 for the Baxi 600/800 Combi and System 2 boilers as “Low system pressure in heating…A.02.18Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomOBD error.Baxi documents A.02.18 for the Baxi 600/800 Combi and System 2 boilers as “OBD error.”. This is the…A.02.36Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomFunctional device disconnected.Baxi documents A.02.36 for the Baxi 600/800 Combi and System 2 boilers as “Functional device disconnected.”. This is…A.02.37Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomPassive functional device disconnected.Baxi documents A.02.37 for the Baxi 600/800 Combi and System 2 boilers as “Passive functional device disconnected.”. This…A.02.45Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomConnection error.Baxi documents A.02.45 for the Baxi 600/800 Combi and System 2 boilers as “Connection error.”. This is the…A.02.46Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomDevice priority error.Baxi documents A.02.46 for the Baxi 600/800 Combi and System 2 boilers as “Device priority error.”. This is…A.02.48Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomUnit function configuration error.Baxi documents A.02.48 for the Baxi 600/800 Combi and System 2 boilers as “Unit function configuration error.”. This…A.02.49Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomFailed node initialisation.Baxi documents A.02.49 for the Baxi 600/800 Combi and System 2 boilers as “Failed node initialisation.”. This is…A.02.54Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomOpenTherm bus power supply error.Baxi documents A.02.54 for the Baxi 600/800 Combi and System 2 boilers as “OpenTherm bus power supply error.”.…A.02.55Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomIncorrect or missing serial number.Baxi documents A.02.55 for the Baxi 600/800 Combi and System 2 boilers as “Incorrect or missing serial number.”.…A.02.76Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomInternal memory reserved for full customisation of settings. No further changes can be made.Baxi documents A.02.76 for the Baxi 600/800 Combi and System 2 boilers as “Internal memory reserved for full…E.00.04Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomReturn temperature sensor disconnected.Baxi documents E.00.04 for the Baxi 600/800 Combi and System 2 boilers as “Return temperature sensor disconnected.”. This…E.00.05Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomReturn temperature sensor short circuited.Baxi documents E.00.05 for the Baxi 600/800 Combi and System 2 boilers as “Return temperature sensor short circuited.”.…E.00.16Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomDHW tank temperature sensor not connected.Baxi documents E.00.16 for the Baxi 600/800 Combi and System 2 boilers as “DHW tank temperature sensor not…E.00.17Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomDHW tank temperature sensor short-circuited.Baxi documents E.00.17 for the Baxi 600/800 Combi and System 2 boilers as “DHW tank temperature sensor short-circuited.”.…E.00.20Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomThe flue gas temperature sensor is not connected or measured a temperature below the range.Baxi documents E.00.20 for the Baxi 600/800 Combi and System 2 boilers as “The flue gas temperature sensor…E.00.21Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomThe flue gas temperature sensor has short-circuited or measured a temperature above the range.Baxi documents E.00.21 for the Baxi 600/800 Combi and System 2 boilers as “The flue gas temperature sensor…E.01.04Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomFlame loss detected five times in 24 hours.Baxi documents E.01.04 for the Baxi 600/800 Combi and System 2 boilers as “Flame loss detected five times…E.01.12Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomTemperature measured by return sensor greater than flow temperature.Baxi documents E.01.12 for the Baxi 600/800 Combi and System 2 boilers as “Temperature measured by return sensor…E.01.17Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomNo water circulation (permanent).Baxi documents E.01.17 for the Baxi 600/800 Combi and System 2 boilers as “No water circulation (permanent).”. This…E.01.20Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomMaximum flue gas temperature reached.Baxi documents E.01.20 for the Baxi 600/800 Combi and System 2 boilers as “Maximum flue gas temperature reached.”.…E.02.13Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomTotal stoppage of the boiler (antifreeze function not active).Baxi documents E.02.13 for the Baxi 600/800 Combi and System 2 boilers as “Total stoppage of the boiler…E.02.17Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomPermanent communication failure between gas valve and boiler PCB.Baxi documents E.02.17 for the Baxi 600/800 Combi and System 2 boilers as “Permanent communication failure between gas…E.02.35Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomCritical safety device disconnected.Baxi documents E.02.35 for the Baxi 600/800 Combi and System 2 boilers as “Critical safety device disconnected.”. This…E.02.39Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomMinimum pressure not reached after 6 minutes of automatic filling.Baxi documents E.02.39 for the Baxi 600/800 Combi and System 2 boilers as “Minimum pressure not reached after…E.02.47Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomConnection to external device unsuccessful.Baxi documents E.02.47 for the Baxi 600/800 Combi and System 2 boilers as “Connection to external device unsuccessful.”.…E.04.01Baxi · Baxi 600/800 Combi and System 2 boilers · United KingdomFlow temperature sensor short circuited.Baxi documents E.04.01 for the Baxi 600/800 Combi and System 2 boilers as “Flow temperature sensor short circuited.”.…