Worcester Bosch · Boilers and HVAC

Worcester Bosch Greenstar 8000 Style and Life gas boiler

Product information, applicable models, official documentation and 109 indexed error-code explanations for Greenstar 8000 Style and Life gas boiler.

Worcester Bosch Greenstar 8000 Style and Life gas boiler
109indexed codes
1named models or series
1official links
Product overview

About Worcester Bosch Greenstar 8000 Style and Life gas boiler

Worcester Bosch Greenstar 8000 Style and Life gas boiler is indexed in the Boilers and HVAC directory for United Kingdom. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Greenstar 8000 Style / Life
Complete directory

All Greenstar 8000 Style and Life gas boiler error codes

Showing 1–30 of 109

1010Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomNo BUS communicationWorcester Bosch documents 1010 for the Greenstar 8000 Style and Life gas boiler as “No BUS communication”. This…1013Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomMaximum combustion point reachedWorcester Bosch documents 1013 for the Greenstar 8000 Style and Life gas boiler as “Maximum combustion point reached”.…1018Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomMaintenance interval expiredWorcester Bosch documents 1018 for the Greenstar 8000 Style and Life gas boiler as “Maintenance interval expired”. This…1021Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomCylinder or hot-water temperature sensor faultWorcester Bosch documents 1021 for the Greenstar 8000 Style and Life gas boiler as “Cylinder or hot-water temperature…1023Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomMaximum run time reachedWorcester Bosch documents 1023 for the Greenstar 8000 Style and Life gas boiler as “Maximum run time reached”.…1025Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomReturn temperature sensor faultWorcester Bosch documents 1025 for the Greenstar 8000 Style and Life gas boiler as “Return temperature sensor fault”.…1068Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomOutside temperature sensor or lambda probe faultWorcester Bosch documents 1068 for the Greenstar 8000 Style and Life gas boiler as “Outside temperature sensor or…1073Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomFlow temperature sensor short circuitWorcester Bosch documents 1073 for the Greenstar 8000 Style and Life gas boiler as “Flow temperature sensor short…1074Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomNo signal from flow temperature sensorWorcester Bosch documents 1074 for the Greenstar 8000 Style and Life gas boiler as “No signal from flow…200Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler in heating modeWorcester Bosch documents 200 for the Greenstar 8000 Style and Life gas boiler as “Boiler in heating mode”.…201Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler in hot water modeWorcester Bosch documents 201 for the Greenstar 8000 Style and Life gas boiler as “Boiler in hot water…202Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler in anti-cycle modeWorcester Bosch documents 202 for the Greenstar 8000 Style and Life gas boiler as “Boiler in anti-cycle mode”.…203Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler in standby with no heat demandWorcester Bosch documents 203 for the Greenstar 8000 Style and Life gas boiler as “Boiler in standby with…204Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomPrimary water temperature above set valueWorcester Bosch documents 204 for the Greenstar 8000 Style and Life gas boiler as “Primary water temperature above…208Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomChimney sweep demandWorcester Bosch documents 208 for the Greenstar 8000 Style and Life gas boiler as “Chimney sweep demand”. This…2085Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomInternal faultWorcester Bosch documents 2085 for the Greenstar 8000 Style and Life gas boiler as “Internal fault”. This is…213Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomTemp difference between supply and return exceeding limitWorcester Bosch documents 213 for the Greenstar 8000 Style and Life gas boiler as “Temp difference between supply…214Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomFan shut down during safety timeWorcester Bosch documents 214 for the Greenstar 8000 Style and Life gas boiler as “Fan shut down during…219Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomSupply or return water too hotWorcester Bosch documents 219 for the Greenstar 8000 Style and Life gas boiler as “Supply or return water…2207Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomLow or missing PWM signal from circulation pumpWorcester Bosch documents 2207 for the Greenstar 8000 Style and Life gas boiler as “Low or missing PWM…222Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomInterruption of the NTC cablingWorcester Bosch documents 222 for the Greenstar 8000 Style and Life gas boiler as “Interruption of the NTC…223Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomFlow temperature sensor wiring interruptedWorcester Bosch documents 223 for the Greenstar 8000 Style and Life gas boiler as “Flow temperature sensor wiring…224Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomSafety temp. limiter has trippedWorcester Bosch documents 224 for the Greenstar 8000 Style and Life gas boiler as “Safety temp. limiter has…227Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomNo flame signal after ignitionWorcester Bosch documents 227 for the Greenstar 8000 Style and Life gas boiler as “No flame signal after…228Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomFlame signal detected without a flameWorcester Bosch documents 228 for the Greenstar 8000 Style and Life gas boiler as “Flame signal detected without…229Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomFlame failed during burner operationWorcester Bosch documents 229 for the Greenstar 8000 Style and Life gas boiler as “Flame failed during burner…232Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler locked by external switching contactWorcester Bosch documents 232 for the Greenstar 8000 Style and Life gas boiler as “Boiler locked by external…233Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomBoiler identification module or electronics faultWorcester Bosch documents 233 for the Greenstar 8000 Style and Life gas boiler as “Boiler identification module or…234Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomGas valve electrical faultWorcester Bosch documents 234 for the Greenstar 8000 Style and Life gas boiler as “Gas valve electrical fault”.…235Worcester Bosch · Greenstar 8000 Style and Life gas boiler · United KingdomConflicting boiler electronics and identification versionsWorcester Bosch documents 235 for the Greenstar 8000 Style and Life gas boiler as “Conflicting boiler electronics and…