Keston · Boilers and HVAC

Keston Combi² C30 and C35 combination boilers

Product information, applicable models, official documentation and 21 indexed error-code explanations for Keston Combi² C30 and C35 combination boilers.

Keston Combi² C30 and C35 combination boilers
21indexed codes
1named models or series
1official links
Product overview

About Keston Combi² C30 and C35 combination boilers

Keston Combi² C30 and C35 combination boilers is indexed in the Boilers and HVAC directory for United Kingdom and Ireland. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Combi² C30; Combi² C35
Complete directory

All Keston Combi² C30 and C35 combination boilers error codes

Showing 1–21 of 21

Blocked Flue/CondensateKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandBlocked Flue/Condensate – Keston Combi² error messageKeston documents “Blocked Flue/Condensate” on the Combi² C30 and C35 as the boiler has detected a flue restriction…DHW Thermistor FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandDHW Thermistor Fault – Keston Combi² error messageKeston documents “DHW Thermistor Fault” on the Combi² C30 and C35 as domestic-hot-water temperature sensor or circuit fault.…Fan FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandFan Fault – Keston Combi² error messageKeston documents “Fan Fault” on the Combi² C30 and C35 as combustion fan or fan-control fault. This is…Flame LossKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandFlame Loss – Keston Combi² error messageKeston documents “Flame Loss” on the Combi² C30 and C35 as the burner flame was lost during operation.…Flame On Before Gas OnKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandFlame On Before Gas On – Keston Combi² error messageKeston documents “Flame On Before Gas On” on the Combi² C30 and C35 as a flame signal was…Flow Thermistor FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandFlow Thermistor Fault – Keston Combi² error messageKeston documents “Flow Thermistor Fault” on the Combi² C30 and C35 as flow-temperature sensor or circuit fault. This…Gas Valve FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandGas Valve Fault – Keston Combi² error messageKeston documents “Gas Valve Fault” on the Combi² C30 and C35 as gas-valve control or electrical-supply fault. This…Ignition LockoutKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandIgnition Lockout – Keston Combi² error messageKeston documents “Ignition Lockout” on the Combi² C30 and C35 as ignition attempts did not establish a safe…Low Mains VoltageKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandLow Mains Voltage – Keston Combi² error messageKeston documents “Low Mains Voltage” on the Combi² C30 and C35 as incoming mains voltage is below the…Low Water PressureKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandLow Water Pressure – Keston Combi² error messageKeston documents “Low Water Pressure” on the Combi² C30 and C35 as heating-system pressure is below the permitted…No Water FlowKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandNo Water Flow – Keston Combi² error messageKeston documents “No Water Flow” on the Combi² C30 and C35 as adequate heating-water circulation was not detected.…Outside Sensor FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandOutside Sensor Fault – Keston Combi² error messageKeston documents “Outside Sensor Fault” on the Combi² C30 and C35 as outside-temperature sensor or circuit fault. This…OverheatKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandOverheat – Keston Combi² error messageKeston documents “Overheat” on the Combi² C30 and C35 as boiler overheat condition. This is the 2023 Combi²…PCB FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandPCB Fault – Keston Combi² error messageKeston documents “PCB Fault” on the Combi² C30 and C35 as boiler printed-circuit-board fault. This is the 2023…Pump Dry RunKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandPump Dry Run – Keston Combi² error messageKeston documents “Pump Dry Run” on the Combi² C30 and C35 as the pump has detected dry-running conditions.…Pump FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandPump Fault – Keston Combi² error messageKeston documents “Pump Fault” on the Combi² C30 and C35 as the boiler pump or its feedback circuit…Pump Rotor BlockedKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandPump Rotor Blocked – Keston Combi² error messageKeston documents “Pump Rotor Blocked” on the Combi² C30 and C35 as the boiler pump rotor is blocked.…Return Thermistor FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandReturn Thermistor Fault – Keston Combi² error messageKeston documents “Return Thermistor Fault” on the Combi² C30 and C35 as return-temperature sensor or circuit fault. This…Room Thermostat FaultKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandRoom Thermostat Fault – Keston Combi² error messageKeston documents “Room Thermostat Fault” on the Combi² C30 and C35 as room thermostat communication, power or demand…Spare PCB Not SetKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandSpare PCB Not Set – Keston Combi² error messageKeston documents “Spare PCB Not Set” on the Combi² C30 and C35 as a replacement pcb has not…Too Many RestartsKeston · Keston Combi² C30 and C35 combination boilers · United Kingdom and IrelandToo Many Restarts – Keston Combi² error messageKeston documents “Too Many Restarts” on the Combi² C30 and C35 as the control has recorded excessive restart…