ACV · Boilers and HVAC

ACV Prestige 24/32 condensing boiler

Product information, applicable models, official documentation and 46 indexed error-code explanations for Prestige 24/32 condensing boiler.

ACV Prestige 24/32 condensing boiler
46indexed codes
1named models or series
1official links
Product overview

About ACV Prestige 24/32 condensing boiler

ACV Prestige 24/32 condensing boiler is indexed in the Boilers and HVAC directory for Europe and United Kingdom. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Prestige Solo 24; Prestige Solo 32; Prestige Excellence 24; Prestige Excellence 32
Complete directory

All Prestige 24/32 condensing boiler error codes

Showing 1–30 of 46

b116ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b116 blocking code – Supply frequency more than 1.5 Hz out of toleranceACV documents b116 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Supply frequency more…b117ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b117 blocking code – Air-pressure switch open while burner is operatingACV documents b117 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Air-pressure switch open…b118ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b118 blocking code – Burner ionisation current too lowACV documents b118 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Burner ionisation current…b119ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b119 blocking code – Gas-pressure switch open while burner is operatingACV documents b119 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Gas-pressure switch open…b24ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b24 blocking code – NTC1 and NTC2 sensor positions reversedACV documents b24 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: NTC1 and NTC2…b25ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b25 blocking code – T1 temperature value too highACV documents b25 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: T1 temperature value…b26ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b26 blocking code – Gas- or water-pressure switch operatedACV documents b26 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Gas- or water-pressure…b43ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b43 blocking code – EPROM parameter values outside toleranceACV documents b43 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: EPROM parameter values…b62ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b62 blocking code – Water pressure too lowACV documents b62 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Water pressure too…b65ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 b65 blocking code – Fan speed incorrectACV documents b65 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Fan speed incorrect.…E00ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E00 error code – Flame anomaly detectedACV documents E00 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Flame anomaly detected.…E02ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E02 error code – No flame after five ignition attemptsACV documents E02 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: No flame after…E03ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E03 error code – Rectifier or gas valve damagedACV documents E03 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Rectifier or gas…E04ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E04 error code – Permanent lockoutACV documents E04 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Permanent lockout. This…E05ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E05 error code – No flame signal detectedACV documents E05 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: No flame signal…E06ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E06 error code – Input error detectedACV documents E06 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Input error detected.…E07ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E07 error code – Gas-valve relay errorACV documents E07 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Gas-valve relay error.…E08ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E08 error code – Air-pressure switch failed to closeACV documents E08 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Air-pressure switch failed…E11ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E11 error code – EPROM errorACV documents E11 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: EPROM error. This…E113ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E113 error code – Incorrect supply voltageACV documents E113 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Incorrect supply voltage.…E114ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E114 error code – Incorrect cascade addressACV documents E114 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Incorrect cascade address.…E115ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E115 error code – Internal controller errorACV documents E115 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Internal controller error.…E12ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E12 error code – Limit thermostat or 24-volt fuse operatedACV documents E12 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Limit thermostat or…E122ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E122 error code – NTC1 or NTC2 sensor deviationACV documents E122 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: NTC1 or NTC2…E123ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E123 error code – NTC1 or NTC2 sensor defectiveACV documents E123 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: NTC1 or NTC2…E124ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E124 error code – NTC1 or NTC2 sensor contact lostACV documents E124 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: NTC1 or NTC2…E13ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E13 error code – Internal controller errorACV documents E13 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Internal controller error.…E17ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E17 error code – Internal controller errorACV documents E17 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: Internal controller error.…E18ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E18 error code – T1 temperature above 110°CACV documents E18 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: T1 temperature above…E19ACV · Prestige 24/32 condensing boiler · Europe and United KingdomACV Prestige 24/32 E19 error code – T2 temperature above 110°CACV documents E19 for the Prestige Solo 24/32 and Prestige Excellence 24/32 MCBA range as: T2 temperature above…