Sime · Brava Slim HE ErP condensing boiler · United Kingdom and Europe

ALL 06 error code

ALL 06 — No flame detected

FaultCurrentAlso: ALL 062 min read
High priority✓ Source verified
Quick answer

What does Sime Brava Slim HE ErP condensing boiler ALL 06 mean?

Sime documents ALL 06 for the Brava Slim HE ErP range as “No flame detected”. The alarm identifies the condition detected by the boiler controls; it does not by itself prove which component has failed.

The code identifies the condition detected by the product; it does not always identify the failed component on its own. Confirm the full code and exact model before ordering parts or attempting a reset.

The Sime Brava Slim HE ErP condensing boiler ALL 06 error code indicates sime documents ALL 06 for the Brava Slim HE ErP range as “No flame detected”. The alarm identifies the condition detected by the boiler controls; it does not by itself prove which component has failed. This guide explains what the code means, the symptoms and likely causes, the checks that are safe to make, and when to stop and arrange an authorised repair.

Symptoms you may notice

The combustion-control system cannot establish or maintain the required safe operating condition.

Common causes

Gas-supply or gas-valve issue, ignition or flame-sensing fault, blocked air/flue path, calibration error, unstable combustion or control-board problem.

Before you start troubleshooting

Use the display, rating label or product menu to confirm the exact model. Similar-looking codes can have different meanings across product generations and regions.

  • Record the complete code before switching the equipment off.
  • Check only user-accessible controls, filters and external connections described in the manual.
  • Do not open gas, refrigerant, combustion or electrical compartments.

Troubleshooting steps

Do not repeatedly reset. A Gas Safe engineer must check gas pressure, valve operation, electrode, ionisation, combustion readings, fan, air inlet, condensate and flue outlet.

Can you fix this error code yourself?

This fault is not intended for user repair. Do not remove covers or test internal components; record the code and contact an authorised technician.

A successful reset is not proof that the underlying issue is fixed. If ALL 06 reappears, note when it happens and give that information to the service engineer.

Reset instructions

Reset only when the official instructions permit it and only after the cause has been corrected. Do not make repeated reset attempts; isolate the boiler and contact qualified personnel if the alarm returns.

Applicable products and models

Sime Brava Slim HE ErP condensing boiler Brava Slim HE 24; 25; 30; 35; 40 ErPBrava Slim HE ErP condensing boilerBrava Slim HE 24; 25; 30; 35; 40 ErPSupported range

When to contact a professional

Contact a qualified Sime heating engineer if ALL 06 returns, prevents operation, involves combustion or a safety device, or requires internal checks.

Frequently asked questions

What does Sime Brava Slim HE ErP condensing boiler ALL 06 mean?

Sime documents ALL 06 for the Brava Slim HE ErP range as “No flame detected”. The alarm identifies the condition detected by the boiler controls; it does not by itself prove which component has failed.

Can I fix Sime Brava Slim HE ErP condensing boiler ALL 06 myself?

This code is not classed as user-fixable. Record it and arrange authorised diagnosis rather than opening the product.

Should I reset the product after code ALL 06?

Reset only when the official instructions permit it and only after the cause has been corrected. Do not make repeated reset attempts; isolate the boiler and contact qualified personnel if the alarm returns.

When should I arrange a repair?

Contact a qualified Sime heating engineer if ALL 06 returns, prevents operation, involves combustion or a safety device, or requires internal checks.