Manufacturer error-code directory

Search manufacturer error codes

Enter a code, manufacturer, model or description to find its meaning and the safest next step.

24 matching results

ALL 01Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 01 — Smoke thermostat interventionSime documents ALL 01 for the Brava Slim HE ErP range as “Smoke thermostat intervention”. The alarm identifies…ALL 02Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 02 — Low water pressure in systemSime documents ALL 02 for the Brava Slim HE ErP range as “Low water pressure in system”. The…ALL 03Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 03 — High water pressure in systemSime documents ALL 03 for the Brava Slim HE ErP range as “High water pressure in system”. The…ALL 04Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 04 — Domestic hot-water sensor faultSime documents ALL 04 for the Brava Slim HE ErP range as “Domestic hot-water sensor fault”. The alarm…ALL 05Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 05 — Delivery sensor faultSime documents ALL 05 for the Brava Slim HE ErP range as “Delivery sensor fault”. The alarm identifies…ALL 06Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 06 — No flame detectedSime documents ALL 06 for the Brava Slim HE ErP range as “No flame detected”. The alarm identifies…ALL 07Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 07 — Safety sensor or thermostat interventionSime documents ALL 07 for the Brava Slim HE ErP range as “Safety sensor or thermostat intervention”. The…ALL 08Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 08 — Flame-detection circuit faultSime documents ALL 08 for the Brava Slim HE ErP range as “Flame-detection circuit fault”. The alarm identifies…ALL 09Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 09 — No water circulating in the systemSime documents ALL 09 for the Brava Slim HE ErP range as “No water circulating in the system”.…ALL 10Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 10 — Auxiliary sensor faultSime documents ALL 10 for the Brava Slim HE ErP range as “Auxiliary sensor fault”. The alarm identifies…ALL 11Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 11 — Gas-valve modulator disconnectedSime documents ALL 11 for the Brava Slim HE ErP range as “Gas-valve modulator disconnected”. The alarm identifies…ALL 12Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 12 — DHW sensor fault in tank modeSime documents ALL 12 for the Brava Slim HE ErP range as “DHW sensor fault in tank mode”.…ALL 13Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 13 — Smoke probe interventionSime documents ALL 13 for the Brava Slim HE ErP range as “Smoke probe intervention”. The alarm identifies…ALL 14Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 14 — Smoke probe faultSime documents ALL 14 for the Brava Slim HE ErP range as “Smoke probe fault”. The alarm identifies…ALL 15Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 15 — Fan check cable disconnectedSime documents ALL 15 for the Brava Slim HE ErP range as “Fan check cable disconnected”. The alarm…ALL 18Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 18 — Condensate level faultSime documents ALL 18 for the Brava Slim HE ErP range as “Condensate level fault”. The alarm identifies…ALL 28Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 28 — Maximum consecutive resets reachedSime documents ALL 28 for the Brava Slim HE ErP range as “Maximum consecutive resets reached”. The alarm…ALL 30Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 30 — Return sensor faultSime documents ALL 30 for the Brava Slim HE ErP range as “Return sensor fault”. The alarm identifies…ALL 37Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 37 — Low mains voltageSime documents ALL 37 for the Brava Slim HE ErP range as “Low mains voltage”. The alarm identifies…ALL 40Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 40 — Incorrect mains frequencySime documents ALL 40 for the Brava Slim HE ErP range as “Incorrect mains frequency”. The alarm identifies…ALL 41Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 41 — Flame lost more than six consecutive timesSime documents ALL 41 for the Brava Slim HE ErP range as “Flame lost more than six consecutive…ALL 42Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 42 — Control-button faultSime documents ALL 42 for the Brava Slim HE ErP range as “Control-button fault”. The alarm identifies the…ALL 43Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 43 — OpenTherm communication faultSime documents ALL 43 for the Brava Slim HE ErP range as “OpenTherm communication fault”. The alarm identifies…ALL 44Sime · Brava Slim HE ErP condensing boiler · United Kingdom and EuropeALL 44 — No-flame valve-opening time anomalySime documents ALL 44 for the Brava Slim HE ErP range as “No-flame valve-opening time anomaly”. The alarm…