Remeha · Boilers and HVAC

Remeha Quinta Ace 30–115 wall-hung gas boiler range

Product information, applicable models, official documentation and 70 indexed error-code explanations for Quinta Ace 30–115 wall-hung gas boiler range.

Remeha Quinta Ace 30–115 wall-hung gas boiler range
70indexed codes
1named models or series
1official links
Product overview

About Remeha Quinta Ace 30–115 wall-hung gas boiler range

Remeha Quinta Ace 30–115 wall-hung gas boiler range is indexed in the Boilers and HVAC directory for United Kingdom. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Quinta Ace 30; Quinta Ace 45; Quinta Ace 55; Quinta Ace 65; Quinta Ace 90; Quinta Ace 115
Complete directory

All Quinta Ace 30–115 wall-hung gas boiler range error codes

Showing 1–30 of 70

A.00.34Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.00.34 – Remeha Quinta Ace 30–115 error codeRemeha documents A.00.34 for the Quinta Ace 30–115 range as “Outside temperature sensor missing”. This is a warning…A.00.42Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.00.42 – Remeha Quinta Ace 30–115 error codeRemeha documents A.00.42 for the Quinta Ace 30–115 range as “Water pressure sensor missing”. This is a warning…A.01.23Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.01.23 – Remeha Quinta Ace 30–115 error codeRemeha documents A.01.23 for the Quinta Ace 30–115 range as “Poor combustion”. This is a warning code on…A.02.06Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.02.06 – Remeha Quinta Ace 30–115 error codeRemeha documents A.02.06 for the Quinta Ace 30–115 range as “Water pressure warning active”. This is a warning…A.02.18Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.02.18 – Remeha Quinta Ace 30–115 error codeRemeha documents A.02.18 for the Quinta Ace 30–115 range as “Object Dictionary configuration error”. This is a warning…A.02.33Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.02.33 – Remeha Quinta Ace 30–115 error codeRemeha documents A.02.33 for the Quinta Ace 30–115 range as “Automatic filling communication timeout”. This is a warning…A.02.76Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.02.76 – Remeha Quinta Ace 30–115 error codeRemeha documents A.02.76 for the Quinta Ace 30–115 range as “Custom-parameter memory full”. This is a warning code…A.02.80Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.02.80 – Remeha Quinta Ace 30–115 error codeRemeha documents A.02.80 for the Quinta Ace 30–115 range as “Cascade controller missing”. This is a warning code…A.08.02Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomA.08.02 – Remeha Quinta Ace 30–115 error codeRemeha documents A.08.02 for the Quinta Ace 30–115 range as “Shower time elapsed”. This is a warning code…E.00.04Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.04 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.04 for the Quinta Ace 30–115 range as “Return temperature sensor open”. This is a locking…E.00.05Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.05 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.05 for the Quinta Ace 30–115 range as “Return temperature sensor short circuit”. This is a…E.00.06Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.06 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.06 for the Quinta Ace 30–115 range as “Return temperature sensor missing”. This is a locking…E.00.07Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.07 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.07 for the Quinta Ace 30–115 range as “Return temperature difference too high”. This is a…E.00.16Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.16 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.16 for the Quinta Ace 30–115 range as “DHW tank sensor open”. This is a locking…E.00.17Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.17 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.17 for the Quinta Ace 30–115 range as “DHW tank sensor short circuit”. This is a…E.00.44Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.44 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.44 for the Quinta Ace 30–115 range as “DHW outlet sensor open”. This is a locking…E.00.45Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.00.45 – Remeha Quinta Ace 30–115 error codeRemeha documents E.00.45 for the Quinta Ace 30–115 range as “DHW outlet sensor short circuit”. This is a…E.01.04Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.01.04 – Remeha Quinta Ace 30–115 error codeRemeha documents E.01.04 for the Quinta Ace 30–115 range as “Five flame-loss events”. This is a locking code…E.01.11Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.01.11 – Remeha Quinta Ace 30–115 error codeRemeha documents E.01.11 for the Quinta Ace 30–115 range as “Fan speed outside operating range”. This is a…E.01.12Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.01.12 – Remeha Quinta Ace 30–115 error codeRemeha documents E.01.12 for the Quinta Ace 30–115 range as “Return temperature higher than flow temperature”. This is…E.01.24Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.01.24 – Remeha Quinta Ace 30–115 error codeRemeha documents E.01.24 for the Quinta Ace 30–115 range as “Repeated combustion errors”. This is a locking code…E.02.13Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.13 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.13 for the Quinta Ace 30–115 range as “External blocking input active”. This is a locking…E.02.15Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.15 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.15 for the Quinta Ace 30–115 range as “External CSU communication timeout”. This is a locking…E.02.17Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.17 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.17 for the Quinta Ace 30–115 range as “Gas-valve-control communication timeout”. This is a locking code…E.02.32Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.32 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.32 for the Quinta Ace 30–115 range as “Automatic filling communication error”. This is a locking…E.02.35Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.35 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.35 for the Quinta Ace 30–115 range as “Safety-critical device disconnected”. This is a locking code…E.02.39Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.39 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.39 for the Quinta Ace 30–115 range as “Insufficient pressure rise during automatic filling”. This is…E.02.47Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.02.47 – Remeha Quinta Ace 30–115 error codeRemeha documents E.02.47 for the Quinta Ace 30–115 range as “Function-group connection failed”. This is a locking code…E.04.00Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.00 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.00 for the Quinta Ace 30–115 range as “Safety parameter error”. This is a locking code…E.04.01Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.01 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.01 for the Quinta Ace 30–115 range as “Flow temperature sensor short circuit”. This is a…