Remeha · Boilers and HVAC

Remeha Quinta Ace 30–115 wall-hung gas boiler range

Product information, applicable models, official documentation and 70 indexed error-code explanations for Quinta Ace 30–115 wall-hung gas boiler range.

Remeha Quinta Ace 30–115 wall-hung gas boiler range
70indexed codes
1named models or series
1official links
Product overview

About Remeha Quinta Ace 30–115 wall-hung gas boiler range

Remeha Quinta Ace 30–115 wall-hung gas boiler range is indexed in the Boilers and HVAC directory for United Kingdom. This page brings the available product context, model references, documentation and diagnostic codes together in one place.

The codes below apply only where the linked code page lists this product or model. Confirm the complete model identifier because manufacturers may reuse the same characters across different ranges, generations and control systems.

An error code describes a condition detected by the product; it does not prove that a named component has failed. Follow the exact manual, avoid repeated resets and use an appropriately qualified technician whenever checks require internal access.

Applicability

Models and series

Quinta Ace 30; Quinta Ace 45; Quinta Ace 55; Quinta Ace 65; Quinta Ace 90; Quinta Ace 115
Complete directory

All Quinta Ace 30–115 wall-hung gas boiler range error codes

Showing 31–60 of 70

E.04.02Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.02 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.02 for the Quinta Ace 30–115 range as “Flow temperature sensor open”. This is a locking…E.04.03Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.03 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.03 for the Quinta Ace 30–115 range as “Maximum flow temperature safety limit exceeded”. This is…E.04.04Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.04 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.04 for the Quinta Ace 30–115 range as “Flue-gas temperature sensor short circuit”. This is a…E.04.05Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.05 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.05 for the Quinta Ace 30–115 range as “Flue-gas temperature sensor open”. This is a locking…E.04.06Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.06 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.06 for the Quinta Ace 30–115 range as “Maximum flue-gas temperature exceeded”. This is a locking…E.04.07Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.07 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.07 for the Quinta Ace 30–115 range as “Flow temperature sensor deviation”. This is a locking…E.04.08Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.08 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.08 for the Quinta Ace 30–115 range as “Safety input open”. This is a locking code…E.04.09Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.09 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.09 for the Quinta Ace 30–115 range as “Gas-valve-control internal error”. This is a locking code…E.04.10Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.10 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.10 for the Quinta Ace 30–115 range as “Unsuccessful burner start”. This is a locking code…E.04.11Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.11 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.11 for the Quinta Ace 30–115 range as “Gas-valve proving system error”. This is a locking…E.04.12Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.12 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.12 for the Quinta Ace 30–115 range as “False flame detected”. This is a locking code…E.04.13Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.13 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.13 for the Quinta Ace 30–115 range as “Fan speed outside operating range”. This is a…E.04.15Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.15 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.15 for the Quinta Ace 30–115 range as “Flue-gas pipe blocked”. This is a locking code…E.04.17Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.17 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.17 for the Quinta Ace 30–115 range as “Gas-valve driver error”. This is a locking code…E.04.23Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.23 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.23 for the Quinta Ace 30–115 range as “Gas-valve-control internal locking”. This is a locking code…E.04.250Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomE.04.250 – Remeha Quinta Ace 30–115 error codeRemeha documents E.04.250 for the Quinta Ace 30–115 range as “Gas-valve relay error”. This is a locking code…H.00.81Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.00.81 – Remeha Quinta Ace 30–115 error codeRemeha documents H.00.81 for the Quinta Ace 30–115 range as “Room temperature sensor missing”. This is a blocking…H.01.00Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.00 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.00 for the Quinta Ace 30–115 range as “Communication error”. This is a blocking code on…H.01.05Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.05 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.05 for the Quinta Ace 30–115 range as “Maximum flow/return temperature difference”. This is a blocking…H.01.08Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.08 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.08 for the Quinta Ace 30–115 range as “Central-heating temperature gradient exceeded”. This is a blocking…H.01.09Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.09 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.09 for the Quinta Ace 30–115 range as “Gas pressure switch condition”. This is a blocking…H.01.14Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.14 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.14 for the Quinta Ace 30–115 range as “Maximum flow temperature exceeded”. This is a blocking…H.01.15Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.15 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.15 for the Quinta Ace 30–115 range as “Maximum flue-gas temperature exceeded”. This is a blocking…H.01.21Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.01.21 – Remeha Quinta Ace 30–115 error codeRemeha documents H.01.21 for the Quinta Ace 30–115 range as “DHW temperature gradient exceeded”. This is a blocking…H.02.00Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.00 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.00 for the Quinta Ace 30–115 range as “Reset in progress”. This is a blocking code…H.02.02Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.02 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.02 for the Quinta Ace 30–115 range as “Waiting for configuration number”. This is a blocking…H.02.03Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.03 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.03 for the Quinta Ace 30–115 range as “Configuration error”. This is a blocking code on…H.02.04Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.04 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.04 for the Quinta Ace 30–115 range as “Parameter error”. This is a blocking code on…H.02.05Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.05 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.05 for the Quinta Ace 30–115 range as “CSU and control-unit mismatch”. This is a blocking…H.02.09Remeha · Quinta Ace 30–115 wall-hung gas boiler range · United KingdomH.02.09 – Remeha Quinta Ace 30–115 error codeRemeha documents H.02.09 for the Quinta Ace 30–115 range as “Partial external block”. This is a blocking code…